歡迎訪問中科光析科學技術研究所官網(wǎng)!
免費咨詢熱線
400-635-0567
液體燃料壁爐檢測項目報價???解決方案???檢測周期???樣品要求? |
點 擊 解 答??![]() |
GB/T 20002的本部分提供了解決兒童使用或接觸產(chǎn)品、過程或服務(盡管它們并非為兒童而專門設計)可能給兒童帶來的意外身體傷害(危險)問題的框架,以便減少對兒童的傷害風險。本部分主要適用于參與標準編制和修訂的人員,也包含了設計師、建筑師、制造商、服務提供者、宣傳者和政策制定者等關注的重要信息。對于有特殊需要的兒童,補充適當?shù)囊笫强扇〉?。本部分并未全面涉及這些補充要求。對于預防或減少心理或精神傷害或故意傷害,本部分沒有提供任何專門的指導。
警告:本標準并不能指出與該標準應用有關的所有安全問題。因此在使用本標準前,使用者有責任建立合適的安全和健康措施,確定適用的規(guī)章限制。本標準覆蓋了通常稱作點火槍(也稱作燒烤打火機、壁爐打火機、點火棒、氣體火柴)的所有能產(chǎn)生火焰的消費品,及類似2.6條款定義的點火裝置。本標準不適用于火柴;也不適用于用以點燃香煙、雪茄和煙斗等產(chǎn)生火焰的產(chǎn)品。
This European Standard specifies requirements relating to the design, manufacture, construction, safety andperformance (efficiency and emission) instructions and marking together with associated test methods andtest fuels for type testing residential roomheaters fired by solid fuel.This Standard is applicable to non-mechanically fired appliances, which are listed under categories 1a and 2aof Table 1. These appliances provide heat into the space where they are installed. Additionally, where fittedwith a boiler, they also provide domestic hot water and/or central heating. These appliances may burn eithersolid mineral fuels, peat briquettes, natural or manufactured wood logs or be multi-fuel in accordance withthe appliance manufacturer’s instructions.This standard is not applicable to appliances with fan assisted combustion air.
This European Standard applies for decorative fireplaces/appliances for domestic use, producing a flame using alcohol, hereafter referred to as fuel, in liquid or gelatinous fuel for decoration. NOTE 1 The requirements are strictly applied even when used in other areas. Outside the private household and outdoor area can apply more or different rules on the use of the appliances. This European Standard applies to free-standing, wall-mounted and built-in appliances with a maximum power output of 4,5 kW. This European Standard applies for appliances ready for use, whose burner is of one unit or are an integral component of the appliances but not for appliances with a fuel tank separate from the appliance. This European Standard does not apply for appliances specifically designed for heating food or keeping food warm (rechauds), as well as for appliances for use in boats, caravans, other vehicles or outdoor areas. This European Standard does not apply for appliances with a power output higher than 4,5 kW or with a defined heating function. NOTE 2 National regulation may restrict the power output to less than 4,5 kW.
La présente Norme européenne spécifie les exigences et les méthodes d'essai pour la conception, la fabrication, la sécurité et l'utilisation rationnelle de l'énergie pour des chaudières standard et des chaudières à basse température (\"chaudière\" au sens de \"corps de chaudière\") en acier et en fonte, devant être équipées de br?leurs à air soufflé commercialisés séparément, conformes aux normes applicables aux br?leurs (pour les br?leurs automatiques à air soufflé pour combustibles gazeux, voir l'EN 676 et pour les br?leurs à fioul à pulvérisation, voir l'EN 267) jusqu'à une puissance utile nominale de 10 MW. Ces chaudières fonctionnent, selon les instructions du fabricant, soit en dépression (à tirage naturel), soit en pression (chaudières pressurisées) dans la chambre de combustion.La présente Norme européenne spécifie les exigences relatives aux chaudières dont la température normale de service est comprise entre 100 oC et 110 oC ; elle est structurée en \"deux volets\"Pour les chaudières dont la température de coupure du thermostat limiteur de sécurité ne dépasse pas 110 oC, la directive relative aux équipements sous pression (DEP) exige l'application des \"règles de l'art en usage\",Pour les chaudières dont la température de coupure du thermostat limiteur de sécurité est supérieure à 110 oC, la présente Norme européenne spécifie les exigences de la DEP indiquées dans l'Annexe ZB.
This Standard applies for decorative fireplaces/appliances for domestic use, producing a flame using alcohol, hereafter referred to as fuel, in liquid or gelatinous fuel for decoration. NOTE 1 The requirements are strictly applied even when used in other areas. Outside the private household and outdoor area can apply more or different rules on the use of the appliances. This Standard applies to free-standing, wall-mounted and built-in appliances with a maximum power output of 4,5 kW. This Standard applies for appliances ready for use, whose burner is of one unit or are an integral component of the appliances but not for appliances with a fuel tank separate from the appliance. This Standard does not apply for appliances specifically designed for heating food or keeping food warm (rechauds), as well as for appliances for use in boats, caravans, other vehicles or outdoor areas. This Standard does not apply for appliances with a power output higher than 4,5 kW or with a defined heating function. NOTE 2 National regulation may restrict the power output to less than 4,5 kW.
This standard specifies the installation and design of oil firing systems with automatic, partly automatic and manually operated oil burners as well their oil supply systems for the fuel EL according DIN 51603-1 for all room installations.#,,#
This standard applies to flued oil stoves with one or more vaporizing burners (hereafter referred to as\"stoves\") as used for individual heating in the domestic field and having either a draught regulator or a combustion air limiter as defined in 3.13 and a nominal heating capacity of not more than 15 kW.This standard also applies to appliances with fan assisted vaporizin9 burners.This standard does not cover-- Built-in appliances-- appliances equipped with an atomizing burner appliances incorporating a boiler or connected to a water system.According to the type of fuels used in the country of destination, the stoves are supplied for use with either: fuel oil with a maximum kinematic viscosity of 6,0 mm<(UP)2>/s at 20 ℃or kerosene with a flash point of not less than 40 ℃.
This European Standard specifies the requirements and test methods for the construction, safety, marking and rational use of energy of open fronted gas-fired independent space heaters with and without a fan to assist with the transportation of flue gases. Although the fan may be mounted outdoors, this standard only covers appliances where the body of the appliance is indoors. This standard applies to types B11AS, B11BS, B14AS, and B14BS open fronted gas-fired independent space heating appliances that incorporate an atmospheric burner, that are connected directly to an open flue or to a device to evacuate the products of combustion (open-flued appliances), that have a nominal heat input not exceeding 20 kW (based on the net calorific value) and that are delivered with the gas-carrying components, burner (s), combustion chamber and heat exchanger fully assembled.
This European standard specifies requirements relating to the design,manufacture,construction,safety and performance(efficiency and emission)instructions and marking together with associated test methods and test fuels for type testing residential slow heat release appliances fired by solid fuel.This European standard is applicable to hand fuelled intermittent burning slow heat release appliances having thermal storage capacity such that they can provide heat for a declared period of time after the fire has gone out.This European standard also specifies a minimum time period from the appliance achieving the maximum differential surface temperature and falling to 50% of that maximum value.These appliances provide heat into the space where they are installed.These slow heat release appliances may be supplied either as an assembled appliance or as manufacturer's pre-designed unit consisting of pre-fabricated components designed to be built on site in accordance with the manufacturer's specified assembly instructions.One off installations are not included.These appliances may burn either solid mineral fuels,peat briquettes,natural or manufactured wood logs or be multi-fuel in accordance with the appliance manufacturer's instructions.Wood pellets which are hand fuelled may also be burned either on the existing appliance bottomgrate or in a special basket arrangement which is placed by the user into the existing firebox.This European standard is not applicable to mechanically fed appliances,appliances having fan assisted combustion air or appliances with boiler.
This European Standard covers multi-firing sauna stoves in which the heating stones are separated from and indirectly heated by the fire and the flue gases and which may be re-fuelled with several fuel loads.
This standard defines the requirements for the construction and operating methods, the operation tests, as well as for the production, labelling and the instruction manuals of decorative fireplaces/appliances producing a flame using liquid or gelatinous alcohol based fuels for domestic use. This draft standard applies to free-standing, wall-mounted and built-in appliances with a maximum power output of 4,5 kW.
This International Standard specifies requirements and gives recommendations for the design,materials,fabrication,inspection,testing,preparation for shipment,and erection of fired heaters,air heaters (APHs),fans and burners for general refinery service.This International Standard is not intended to apply to the design of steam reformers or pyrolysis furnaces.
This part of ISO 16000 specifies the planning of nitrogen dioxide indoor pollution measurements. In the caseof indoor air measurements, the careful planning of sampling and the entire measurement strategy are ofparticular significance since the result of the measurement may have far-reaching consequences, forexample, with regard to ascertaining the need for remedial action or the success of such an action.An inappropriate measurement strategy may lead to misrepresentation of the true conditions or, worse, toerroneous results.