亚洲av日韩av不卡在线电影-日韩亚洲欧洲中文字幕无-91亚洲视频久久久久区-www日韩中文字幕在线看

歡迎訪問中科光析科學技術研究所官網!

您的位置:首頁 > 其他

端子臺檢測

發(fā)布日期: 2024-06-21 17:34:53 - 更新時間:2024年06月29日 15:22

端子臺檢測項目報價???解決方案???檢測周期???樣品要求?

點 擊 解 答??

CNS 9808-1983控制機具絕緣距離、絕緣電阻及耐電壓試驗法

本標準適用于頻率 50 Hz 或 60 Hz 交流 600 V 或直流 750 V 以下電路中所使用控制機具絕緣距離,絕緣電阻及耐電壓試驗法。1.1 本標準所稱制機器包括托觸器、電阻器、控制用開關、電驛、限制開關、端子臺等及其組合裝置,及半導體裝置。

CNS 60715-2018低電壓開關裝置及控制裝置之尺度-為開關裝置、控制裝置及配件提供機械性支撐并達成標準化安裝之導軌

本標準針對為開關裝置、控制裝置及配件提供安裝相容性之部分型式導軌,規(guī)定其功能性要求與尺度。本標準之目的系規(guī)定對于正確設計安裝用導軌及設備為關鍵之尺度。本標準涵蓋下列截面形狀之導軌:- 〝頂帽〞形截面(〝top hat〞section)。- 〝C〞形截面。- 〝G〞形截面。備考1.安裝相容性不代表功能之可互換性。附錄中列舉可滿足本標準要求之特定鋼制導軌,并提供適用之尺度資料及負荷要求。備考2.附錄中提供特定鋼制導軌之細部設計與材質。備考3.其他截面形狀之導軌可符合本標準但未列于附錄A中時,亦可使用。使用導電性連接方法連接至保護性導體端子臺以作為保護性導體之安裝用導軌,參照IEC 60947-7-2。對于其他應用,例如以安裝用導軌作為接地導體,則適用相關產品標準。

ITU-R F.592-4-2007固定業(yè)務中的術語詞匯表

This Recommendation provides vocabulary of basic terms used in other ITU-R Recommendations or Reports in relation to the fixed service. These terms are arranged in several categories with their definitions. Important acronyms and abbreviations that appear frequently in many Recommendations are also listed.

ITU-R F.592-4 FRENCH-2007固定業(yè)務中的術語詞匯表

This Recommendation provides vocabulary of basic terms used in other ITU-R Recommendations or Reports in relation to the fixed service. These terms are arranged in several categories with their definitions. Important acronyms and abbreviations that appear frequently in many Recommendations are also listed.

ITU-R F.592-4 SPANISH-2007固定業(yè)務中的術語詞匯表

This Recommendation provides vocabulary of basic terms used in other ITU-R Recommendations or Reports in relation to the fixed service. These terms are arranged in several categories with their definitions. Important acronyms and abbreviations that appear frequently in many Recommendations are also listed.

ITU-R INFORME SM.2092 SPANISH-2007積極的服務分配在相鄰或附近的區(qū)域對地球勘探衛(wèi)星服務(被動)相關的影響的研究

The passive radio astronomy service (RAS) is studying natural phenomena producing radio emissions at frequencies fixed by the laws of nature. Primary allocations have been made to various space services in the Earth-to-space direction such as the fixed-satellite service (FSS), radionavigation-satellite service (RNSS), mobile-satellite service (MSS) and broadcasting-satellite service (BSS) in bands adjacent or nearby to bands allocated to the RAS.

UL 38-2008火災報警系統(tǒng)用手動信令盒

1.1 These requirements cover manual signaling boxes for fire alarm systems intended for permanentinstallation and used in ordinary locations in accordance with the National Electrical Code, NFPA 70, and the National Fire Alarm Code, NFPA 72.1.2 A manual signaling box is an assembly of a mechanism having electrical contacts designed totransmit a signal when an integral part is operated manually. The signaling contacts are intended to beconnected to circuits of fire alarm systems. The types of boxes covered by these requirements are coded boxes and non-coded boxes, including signaling boxes, fire and guard’s tour reporting stations, and guard’s tour reporting stations for suppressed-signal tour combinations.1.3 A manual signaling box having a pre-wound signaling mechanism and equipped with a trippingelectromagnet to permit automatic actuation by separate detectors, and similar combination devices, shall be evaluated with regard to compliance with the applicable requirements for both manual signaling boxes and electrically-actuated transmitters.1.4 A manual signaling box shall be constructed for use with system-control units, electrically-actuatedtransmitters, or similar units that will permit its application in compliance with applicable codes andstandards of the National Fire Protection Association.1.5 These requirements do not cover electrically-actuated transmitters.

UL 346-2005防火信號系統(tǒng)用水流量指示器

1.1 These requirements cover vane type waterflow indicators intended for use in fire protective signaling systems to be employed in ordinary indoor locations, in accordance with the National Fire Alarm Code, NFPA 72. 1.2 Waterflow indicators covered by these requirements include sizes 3/4 inch and larger. The indicator sizes refer to the nominal inside diameter of the main sprinkler pipe or tubing on which they are installed. 1.3 A vane type waterflow indicator is an assembly of a mechanism having electrical contacts arranged to transmit a coded or noncoded signal when the vane, located in the supply pipe (riser) of a sprinkler system, is moved by the flow of water in the pipe. This flow is normally caused by the opening of one or more sprinkler heads resulting from a fire condition. The signaling contacts are intended to be connected to circuits of private fire protective signaling systems. 1.4 These requirements do not cover pressure-operated waterflow indicators.

UL SUBJECT 2755-2011模塊化數據中心的研究概況

1.1 This Outline of Investigation covers Modular Data Centers (MDC). The Modular Data Centers coveredby these requirements are pre-fabricated units consisting of an outer enclosure housing ITE and varioussupport equipment such as electrical service and distribution equipment, HVAC systems and the like.Some configurations may have the support equipment housed in a separate enclosure. A typicalconstruction may use a standard ISO shipping container or other structure as the outer enclosure, racksor cabinets of ITE, NEC compliant service entrance equipment and power distribution components, powerstorage such as a UPS and an air or liquid cooling system.1.2 These factory-built modules incorporate pre-installed materials and equipment which, afterinstallation, may be concealed and may not be accessible for inspection at the final installation site.1.3 The modular data centers covered by these requirements are intended for fixed installation eitherindoors or outdoors based on their construction and resistance to environmental conditions. MDCsintended for outdoor use shall be identified with a NEMA environmental class rating.1.4 These requirements are intended to demonstrate compliance with the National Electrical Code (NEC),NFPA 70 and other national Codes such as Building, Fire, Plumbing, Mechanical, and the like. Wherestate or local codes differ from the national codes anticipated by these requirements, determiningcompliance with these codes is the responsibility of the local authority having jurisdiction.1.5 When these requirements do not cover a specific technology or construction feature, the applicablerequirements of the National Codes shall be used.1.6 This Outline of Investigation assumes that the final installation of the MDC will be performed byqualified service personnel in accordance with the applicable installation instructions, installation practicesand national installation codes. These MDCs are intended for installation subject to approval by theAuthority Having Jurisdiction.

JRIS R0137-2021機車車輛.低壓電路的接線板

この規(guī)格は,鉄道車両に用いる低圧補助回路端子臺類の性能及び構造について規(guī)定する。端子臺は,電線の分岐及び接続を目的とし,主として,低圧つなぎ箱,配電盤などに使用する。

上一篇:PCB式端子臺檢測 下一篇:商用車輛行車制動器總成及摩擦襯片(塊)總成檢測
以上是中析研究所端子臺檢測檢測服務的相關介紹,如有其他檢測需求可咨詢在線工程師進行了解!

京ICP備15067471號-35版權所有:北京中科光析科學技術研究所